Articles

Primary Leads

Factory moulded primary connectors

FAA L-823 Type I Class A
Prefabricated, moulded primary connectors ready for use. Possibility to have plug receptacle or extension cord which have plug in the other end of the cable and receptacle in the other end of the cable.
Connectors are moulded on the one core AWG 8 (8,3mm2) cable. Diameter of the cable is approximately 10mm. Insulation material is thermoplastic rubber with excellent electrical and mechanical characteristics and good fluid resistance. Connector insulation makes perfectly watertight joint with the thermoplastic rubber insulated cable. Connector ratings are 25A/6000V.
180x75_primaryleads.jpg
Efla Type Description
KDCP 510.8.x Plug FAA L-823 Style 2 other cable end free
KDCR 510.8.x Receptacle FAA L-823 Style 9 other cable end free
KDCE 510.8.x Extension cord FAA L-823 Style 2 and Style 9
X indicates length of the cable in centimeters (for example KDCP510.8.300 is a plug FAA Style 2 with 3m cable)

KDC500-Prefabricated Primary Leads

Prefabricated primary leads with FAA 150/5345-26D interfaces.

Ready made connections and passed electrical production test reports are time saving options that provides easy and quick installation performance once installation time is limited.

Each and every lead tested visually and interface dimensions checked using gauge instruments. Leads are then subjected to a dielectric and continuity test during the validation of a production run.
Test voltage for KDC500 is 15 kV dc.

Test reports are included once requested

Specification
Plug Type I, Class A, Style 2
Receptacle Type 1, Class A, Style 9
Rating: 25 Amperes /5kV:
Length: with desired screened or unscreened cable lengths