AGL Series Transformers

Efla’s AGL transformers are designed and manufactured to meet the requirements of IEC 61823, FAA AC 150/5345-47B and ICAO Aerodrome Design Manual: Part 5 Electrical Systems. The transformers are available from 30/45 W to 300 W, alternatively with or without earthing. Toroidal core has the optimal shape for a transformer which allows a design with excellent properties. All transformers are exposed to comprehensive test procedure.

AGL series transformers are equipped with primary connectors FAA –L 823 Style 2 and Style 9. Standard length of primary leads is 0,6m. The length of the secondary lead is 1,2m containing either FAA-L823 Style7 (standard) or Style 8 connector.

 
Test Results

All test results are recorded and can be supplied with the delivery if EFLA is informed when ordered.

Afterwards Test reports can be supplied only if the id-number of transformer is informed to EFLA (Sticker on secondary lead).
Efla Type FAA Type Nominal
Rating
[W]
Current
Rating
[A]
Max Primary
Circuit
Voltage
[V]
Frequency
[Hz]
Min PF
With
Earthing
Without
Earthing
  ETL CERTIFIED          
KR 531 KR 531.1 L-803-1
L-831-1
30/45 6.6/6.6 5000 50/60 0.97
KR 536 KR 536.1 L-830-3
L-831-3
65 6.6/6.6 5000 50/60 0.97
KR 541 KR 541.1 L-830-4
L-831-4
100 6.6/6.6 5000 50/60 0.97
KR 546 KR 546.1 L-830-19
L-831-19
150 6.6/6.6 5000 50/60 0.97
KR 551 KR 551.1 L-830-6
L-831-6
200 6.6/6.6 5000 50/60 0.97
KR 561 KR 561.1 L-830-10
L-831-10
300 6.6/6.6 5000 50/60 0.97
Available also with current ratings 20A/6,6A and 8.3A/6,6A. (Efla types for example KR531.20 and KR551.83.1)